AAC Autoclave and Boiler

Short Description:

Autoclave is a large steam equipment, can be used for steam sand lime brick, fly ash bricks, aerated concrete blocks, high-strength concrete poles, pipe pile and other cement products, also suitable for wood, medicine, chemical, glass, insulation materials and other materials.


  • Internal Diameter: ≥1.65m
  • Operating Temperature: 184-201℃
  • Working Pressure: 1.0-1.6MPa
  • Working Medium: Saturation Steam
  • Application: Flyash Block Plant,Building Material, AAC Plant,
  • Product Detail

    Autoclave Characteristics

    1 The autoclave is steel horizontal tube-type device, the autoclave lid is pressed by the whole block 16MnR steel, the flange of autoclave body and autoclave lid is used the 16Mn steel in the whole forging processing. The weld parts have been heat treatment and strict nondestructive testing in accordance with relevant standards.
    2. Autoclave door is activity Open structure by hand-reducer. The clients can also choice the electric, pneumatic, hydraulic style to open and close.
    Equipped with a perfect safety interlock protection device to maximum avoid mistake operation, and to ensure the safe operation of the autoclave and operator safety production.
    The autoclave door has two types for the user to choose : 1. Side open 2. Up Open. Side open style adopts Rotating arm side open door structure, rotating flexible, low place operating , easy to operate . Up Open style adopts leveraged open door structure, the lower end of leverage connect with the autoclave door , the upper end equipped lift equipment, this type is portable to open, and small space in the autoclave side.
    3. The autoclave door seal is imported rubber seals by professional manufacturers , simple installation, good sealing and long service life.
    The autoclave body bearing has equipped the three style of fixed bearing, move bearing and end special bearing in different parts. It is best to be suitable for the thermal expansion and contraction of autoclave, to ensure the normal work of the autoclave and useful life.
    4. The autoclave has a safety valve, pressure gauge, temperature measurement devices, inlet and exhaust valves, sealing ball valves, steam traps and other necessary valves and instrumentation, and equipped with decontamination tank for the user optional.
    5. Besides the normal steam distribution pipes and guide rails, we specially set up the sealed steam protection cover and
    Conventional steam distribution pipes and rails parts except the kettle, we more the sake of customers, set up a special sealed vapor scour protection cover and drain cover.
    6. The autoclave design advanced and rigorous production, strictly follow the National Pressure Vessel Code.

    Autoclave Specification

    Autoclave Series

    Main Technology Parameter List

    ModelItem FGZCS1.0-1.65x21 FGZCS1.3-2x21 FGZCS1.3-2x22 FGZCS1.3-2x26 FGZCS1.3-2x27.5 FGZCS1.3-2x30
    Inside Diameter     mm

    1650

    2000

    2000

    2000

    2000

    2000

    Effective Length     mm

    21000

    21000

    22000

    26000

    27500 30000
    Design Pressure     Mpa

    1.08

    1.4

    1.4

    1.4

    1.4

    1.4

    Design Temperature  

    187

    197.3

    197.3

    197.3

    197.3

    197.3

    Working Pressure   Mpa

    1.0

    1.3

    1.3

    1.3

    1.3

    1.3

    Working Temperature

    183

    193.3

    193.3

    193.3

    193.3

    193.3

    Actuating Medium

    Saturated Steam , condensed water

    Inside Rail Distance  mm

    600

    448

    600

    750

    600

    600

    Effective Volume     m3

    46

    68

    71

    84

    88.5

    96.4

    Gross Weight        Kg

    18830

    25830

    26658

    30850

    32170

    34100

    Overall Dimension   mm

    21966x

    2600x2803

    22300x

    2850x3340

    23300x2850x3340

    27300x

    2850x3340

    28800x

    2850x3340

    31300x

    2850x3340

     

    ModelItem FGZCS1.5-2.68x22.5 FGZCS1.5-2.68x26 FGZCS1.5-2.68x39 FGZCS1.5-2.85x21 FGZCS1.5-2.85x23
    Inside Diameter     mm

    2680

    2680

    2680

    2850

    2850

    Effective Length     mm

    22500

    26000

    39000

    21000

    23000
    Design Pressure     Mpa

    1.6

    1.6

    1.6

    1.6

    1.6

    Design Temperature  

    204

    204

    204

    201.3

    203

    Working Pressure   Mpa

    1.5

    1.5

    1.5

    1.5

    1.5

    Working Temperature

    200

    200

    200

    197.3

    199

    Actuating Medium

    Saturated Steam , condensed water

     
    Inside Rail Distance  mm

    800

    800

    800

    1000

    963

    Effective Volume     m3

    134

    154.2

    227.5

    137

    150

    Gross Weight        Kg

    45140

    46700

    67480

    45140

    44565

    Overall Dimension   mm

    24180x

    3850x4268

    27650x

    3454x4268

    40650x3454x4268

    22634x

    3462x4495

    24900x

    3490x4500

     

    ModelItem FGZCS1.5-2.85x24 FGZCS1.5-2.85x25 FGZCS1.5-2.85x26 FGZCS1.5-2.85x26.5 FGZCS1.5-2.85x27
    Inside Diameter     mm

    2850

    2850

    2850

    2850

    2850

    Effective Length     mm

    24000

    25000

    26000

    26500

    27000
    Design Pressure     Mpa

    1.6

    Design Temperature  

    203

    Working Pressure   Mpa

    1.5

    Working Temperature

    199

    Actuating Medium

    Saturated Steam , condensed water

     
    Inside Rail Distance  mm

    963

    849

    963

    900

    915

    Effective Volume     m3

    150

    161

    170

    173

    180

    Gross Weight        Kg

    46035

    48030

    54530

    54880

    55600

    Overall Dimension   mm

    25900x

    3490x4500

    26640x

    3640x4495

    27634x3640x4495

    28134x

    3462x4495

    28640x

    3640x4495

     

    ModelItem FGZCS1.5-2.85x29 FGZCS1.5-2.85x36 FGZCS1.5-3x23 FGZCS1.5-3x31 FGZCS1.5-3.2x24.5
    Inside Diameter     mm

    2850

    2850

    3000

    3000

    3200

    Effective Length     mm

    29000

    36000

    23000

    31000 32000
    Design Pressure     Mpa

    1.6

    Design Temperature  

    203

    Working Pressure   Mpa

    1.5

    Working Temperature

    199

    Actuating Medium

    Saturated Steam , condensed water

     
    Inside Rail Distance  mm

    963

    900

    1220

    1000

    1200

    Effective Volume     m3

    190

    234

    167

    227

    206

    Gross Weight        Kg 58400

    70020

    56765

    70410

    62440
    Overall Dimension   mm 30634x3640x4495 37634x3462x4495 24875x3516x4804 32875x3516x4804 26570x3750x5027

  • Previous:
  • Next:

  • Write your message here and send it to us

    Related products

    • Biomass Steam Boiler

      Biomass Steam Boiler

      Biomass Boiler-Hot Sale- Easy Installation Low Heating Value Fuel Wood Rice Husk Pellets etc. Introduction : Biomass Steam Boiler is horizontal three-back water fire pipe composite boiler. Fix fire tube in drum and the light pipe water wall is fixed on the right and left sides of the furnace. With light chain grate stoker for mechanical feeding and by the draft fan and blower for mechanical ventilation, realize mechanical taphole by scraper slag remover. The hopper of fuel drops to ...

    • Double Drum Steam Boiler

      Double Drum Steam Boiler

      Coal Steam Boiler-Used in Foods, Textile, Plywood,Paper Brewery,Rice Mill etc.. Introduction : SZL Series assembled water tube boiler adopts longitudinal double drum chain grate boiler. The boiler body is composed of up& down longitudinal drums and convection tube, best heating surface, high thermal efficiency, reasonable design, compact structure, elegant appearance, adequate effect. Two side of Combustion chamber equipped the light pipe water wall tube, up drum equip steam ...

    • Gas Steam Boiler

      Gas Steam Boiler

      Introduction : WNS series steam boiler burning oil or gas is Horizontal internal combustion three backhaul fire tube boiler, adopts boiler furnace wet back structure, high temperature smoke, gas turn to scour the second and third backhaul smoke tube plate, then after the smoke chamber. discharged into the atmosphere through the chimney. There are the front and back Smokebox Cap in the boiler, easy to maintenance. Excellent burner adopts combustion automatic ratio adjustment , feedwater ...

    • SZS Gas Oil PLG Boiler

      SZS Gas Oil PLG Boiler

      Introduction : SZS series boiler body is longitudinal 2-drum, D-type chamber combustion strueture. The furnace is on right side and the convection bank tube is on left side. The body is fixed on the body chassis by flexible supports in the middle and two ends of the lower drum,can secure to let the whole boiler body to expand sideways. Surround furnace there are narrow space membrane cooling tube wall. It is totally sealed and separated between the membrane wall on furnace left side and the c...