We are experienced manufacturer. Wining the majority of the crucial certifications of its market for heavy oil hot water boiler, chinese boiler technology, electric control containerelectric control panel, We adhere to the tenet of "Services of Standardization, to Meet Customers' Demands".
Reasonable price Boiler Power Plant - AAC Autoclave and Boiler – Double Rings Detail:

Autoclave Characteristics

1 The autoclave is steel horizontal tube-type device, the autoclave lid is pressed by the whole block 16MnR steel, the flange of autoclave body and autoclave lid is used the 16Mn steel in the whole forging processing. The weld parts have been heat treatment and strict nondestructive testing in accordance with relevant standards.
2. Autoclave door is activity Open structure by hand-reducer. The clients can also choice the electric, pneumatic, hydraulic style to open and close.
Equipped with a perfect safety interlock protection device to maximum avoid mistake operation, and to ensure the safe operation of the autoclave and operator safety production.
The autoclave door has two types for the user to choose : 1. Side open 2. Up Open. Side open style adopts Rotating arm side open door structure, rotating flexible, low place operating , easy to operate . Up Open style adopts leveraged open door structure, the lower end of leverage connect with the autoclave door , the upper end equipped lift equipment, this type is portable to open, and small space in the autoclave side.
3. The autoclave door seal is imported rubber seals by professional manufacturers , simple installation, good sealing and long service life.
The autoclave body bearing has equipped the three style of fixed bearing, move bearing and end special bearing in different parts. It is best to be suitable for the thermal expansion and contraction of autoclave, to ensure the normal work of the autoclave and useful life.
4. The autoclave has a safety valve, pressure gauge, temperature measurement devices, inlet and exhaust valves, sealing ball valves, steam traps and other necessary valves and instrumentation, and equipped with decontamination tank for the user optional.
5. Besides the normal steam distribution pipes and guide rails, we specially set up the sealed steam protection cover and
Conventional steam distribution pipes and rails parts except the kettle, we more the sake of customers, set up a special sealed vapor scour protection cover and drain cover.
6. The autoclave design advanced and rigorous production, strictly follow the National Pressure Vessel Code.

Autoclave Specification

Autoclave Series

Main Technology Parameter List

ModelItem FGZCS1.0-1.65×21 FGZCS1.3-2×21 FGZCS1.3-2×22 FGZCS1.3-2×26 FGZCS1.3-2×27.5 FGZCS1.3-2x30
Inside Diameter     mm

1650

2000

2000

2000

2000

2000

Effective Length     mm

21000

21000

22000

26000

27500 30000
Design Pressure     Mpa

1.08

1.4

1.4

1.4

1.4

1.4

Design Temperature  

187

197.3

197.3

197.3

197.3

197.3

Working Pressure   Mpa

1.0

1.3

1.3

1.3

1.3

1.3

Working Temperature

183

193.3

193.3

193.3

193.3

193.3

Actuating Medium

Saturated Steam , condensed water

Inside Rail Distance  mm

600

448

600

750

600

600

Effective Volume     m3

46

68

71

84

88.5

96.4

Gross Weight        Kg

18830

25830

26658

30850

32170

34100

Overall Dimension   mm

21966x

2600×2803

22300x

2850×3340

23300x2850x3340

27300x

2850×3340

28800x

2850×3340

31300x

2850×3340

 

ModelItem FGZCS1.5-2.68×22.5 FGZCS1.5-2.68×26 FGZCS1.5-2.68x39 FGZCS1.5-2.85×21 FGZCS1.5-2.85×23
Inside Diameter     mm

2680

2680

2680

2850

2850

Effective Length     mm

22500

26000

39000

21000

23000
Design Pressure     Mpa

1.6

1.6

1.6

1.6

1.6

Design Temperature  

204

204

204

201.3

203

Working Pressure   Mpa

1.5

1.5

1.5

1.5

1.5

Working Temperature

200

200

200

197.3

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

800

800

800

1000

963

Effective Volume     m3

134

154.2

227.5

137

150

Gross Weight        Kg

45140

46700

67480

45140

44565

Overall Dimension   mm

24180x

3850×4268

27650x

3454×4268

40650x3454x4268

22634x

3462×4495

24900x

3490×4500

 

ModelItem FGZCS1.5-2.85×24 FGZCS1.5-2.85×25 FGZCS1.5-2.85x26 FGZCS1.5-2.85x26.5 FGZCS1.5-2.85x27
Inside Diameter     mm

2850

2850

2850

2850

2850

Effective Length     mm

24000

25000

26000

26500

27000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

849

963

900

915

Effective Volume     m3

150

161

170

173

180

Gross Weight        Kg

46035

48030

54530

54880

55600

Overall Dimension   mm

25900x

3490×4500

26640x

3640×4495

27634x3640x4495

28134x

3462×4495

28640x

3640×4495

 

ModelItem FGZCS1.5-2.85×29 FGZCS1.5-2.85×36 FGZCS1.5-3x23 FGZCS1.5-3x31 FGZCS1.5-3.2x24.5
Inside Diameter     mm

2850

2850

3000

3000

3200

Effective Length     mm

29000

36000

23000

31000 32000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

900

1220

1000

1200

Effective Volume     m3

190

234

167

227

206

Gross Weight        Kg 58400

70020

56765

70410

62440
Overall Dimension   mm 30634x3640x4495 37634x3462x4495 24875x3516x4804 32875x3516x4804 26570x3750x5027

Product detail pictures:

Reasonable price Boiler Power Plant - AAC Autoclave and Boiler – Double Rings detail pictures

Reasonable price Boiler Power Plant - AAC Autoclave and Boiler – Double Rings detail pictures

Reasonable price Boiler Power Plant - AAC Autoclave and Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

Our personnel are generally within the spirit of "continuous improvement and excellence", and using the excellent top quality goods, favorable rate and superior after-sales expert services, we try to win every customer's believe in for Reasonable price Boiler Power Plant - AAC Autoclave and Boiler – Double Rings , The product will supply to all over the world, such as: Moscow, Barbados, Bhutan, We are proud to supply our products to every auto fan all around the world with our flexible, fast efficient services and strictest quality control standard which has always approved and praised by customers.
  • On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Maggie from Comoros - 2017.07.07 13:00
    We have worked with many companies, but this time is the best,detailed explanation, timely delivery and quality qualified, nice!
    5 Stars By Gail from Austria - 2018.06.19 10:42
    Write your message here and send it to us

    Related products

    • China Gold Supplier for Boiler Manufacturing - Boiler Valve and Meter – Double Rings

      China Gold Supplier for Boiler Manufacturing -...

      Quality Control 1 Strength Calculation Report for Applied Materials after Inspection Machine inspected. 2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod; 3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler; 4 Hydraulic test report:ensure the standard working pressure and safety; 5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province 6 Manufacturer Produc...

    • High reputation Boiler Wood - Coal Boiler Biomass Boiler Reducer – Double Rings

      High reputation Boiler Wood - Coal Boiler Biom...

      Reducer used in DR Boiler • The main parts adopt high quality carbon structural refined steel.With high strength, high transmission efficiency and reliable operation, long service life, etc. • Respectively using multilevel, stepless frequency conversion speed regulating mode. User can reasonably match speed reducer according to the different operation condition of boiler.With the features of easy operation, energy saving, etc • With characteristics of large transmission torque and speed...

    • Big discounting Boiler For Hot Water Heating System - Biomass Hot Water Boiler – Double Rings

      Big discounting Boiler For Hot Water Heating Sy...

      Introduction : Biomass boiler is horizontal three-back water fire pipe composite boiler. The fuel can be Biomass,coal,wood,rice husk,shells,pellets,bagasse,waste etc.. Display Feature: 1. High thermal efficiency 2. By mechanize operation, reduce intensity of labour of stoker. 3. Easy for installation, when on site, only install slag remover, valve, pipe, water and power, etc., the boiler can be launched into running, additionally, the firing is fast. 4. Easy for installation and moving, save...

    • Special Design for Heating Water Boiler - Coal Boiler Biomass Boiler Multi-Tube Dust Cleaner – Double Rings

      Special Design for Heating Water Boiler - Coal...

      Used in Boiler Multi-tube dust collector belongs to cyclone type dry dust collector, mainly used for boiler and industrial dust collection. Multi-tube dust collector, a kind of cyclone dust collector. Many small cyclone dust collectors (also called cyclones) are combined in a shell and used in parallel. The diameter of the cyclone varies from 100 to 250 mm and can effectively trap 5 to 10 μm dust. It is cast with wear-resistant cast iron and can handle gas with high dust concentration (...

    • 100% Original Boiler Equipment - Biomass Wood Thermal Oil Boiler – Double Rings

      100% Original Boiler Equipment - Biomass Wood ...

      Thermal Oil Boiler used in Textile,Foods, Rubber ,Paper, Plastic, Wood, Building Materials etc. Feature: 1.Overall structure is reasonable and compact, easy to install. 2.Advanced design, Complete structure 3. Simple water cycle, reasonable structure of pressure parts, guarantee water quality, safe to run 4. Complete Ancillary equipment, advanced comprehensive technology

    • OEM China Diesel Hot Water Boiler - Boiler Flue – Double Rings

      OEM China Diesel Hot Water Boiler - Boiler Flu...

      Used in Boiler Introduction Industrial smoke exhaust, air into the pipe, the pipe is equipped with a damper (valve) to regulate the wind speed and pressure in the pipe. It is composed of furnace wall, partial heating surface pipe and cladding wall pipe to guide the flow of smoke, and through each heating surface for heat exchange, divided into horizontal flue and tail flue. The main smoke duct section size of the large capacity boiler is very large, in order to bear and transfer the loa...