OEM/ODM Supplier Water Gas Boiler - Autoclave and Boiler – Double Rings

Short Description:


Product Detail

Related Video

Feedback (2)

We are experienced manufacturer. Wining the majority from the crucial certifications of its market for power plant boilersupercritical boilerboiler in thermal power planttypes of boilers in power plantboiler in steam power plantCFB boiler, Package Boiler, shl type industrial boiler, Besides, our enterprise sticks to high-quality and fair value, and we also offer you fantastic OEM solutions to several famous brands.
OEM/ODM Supplier Water Gas Boiler - Autoclave and Boiler – Double Rings Detail:

Autoclave-Popular used in ACC Plant,Flyash Plant,Building Material etc..

Autoclave Feature

1, the first domestic production of autoclave professional factory.
2, assembly line production, welding all the automation, quality and stability.
3, all the pressure components 100% X-ray film detection, advanced detection methods.
4, the product as a whole factory, advanced and reasonable structure, short installation period, the investment cost is low.
5, fully furnished, by manual or computer control.
    Autoclave use:
    Autoclave steam curing equipment for large, can be used for steam-cured sand lime bricks, fly ash bricks, aerated concrete blocks, high-strength concrete pole, pipe and other concrete products, but also for timber, medicine, chemical industry, glass, insulation materials and other industries.
autoclave and boiler ACC

Autoclave Specification

Autoclave Series

Main Technology Parameter List

ModelItem FGZCS1.0-1.65×21 FGZCS1.3-2×21 FGZCS1.3-2×22 FGZCS1.3-2×26 FGZCS1.3-2×27.5 FGZCS1.3-2x30
Inside Diameter     mm

1650

2000

2000

2000

2000

2000

Effective Length     mm

21000

21000

22000

26000

27500 30000
Design Pressure     Mpa

1.08

1.4

1.4

1.4

1.4

1.4

Design Temperature  

187

197.3

197.3

197.3

197.3

197.3

Working Pressure   Mpa

1.0

1.3

1.3

1.3

1.3

1.3

Working Temperature

183

193.3

193.3

193.3

193.3

193.3

Actuating Medium

Saturated Steam , condensed water

Inside Rail Distance  mm

600

448

600

750

600

600

Effective Volume     m3

46

68

71

84

88.5

96.4

Gross Weight        Kg

18830

25830

26658

30850

32170

34100

Overall Dimension   mm

21966x

2600×2803

22300x

2850×3340

23300x2850x3340

27300x

2850×3340

28800x

2850×3340

31300x

2850×3340

 

ModelItem FGZCS1.5-2.68×22.5 FGZCS1.5-2.68×26 FGZCS1.5-2.68x39 FGZCS1.5-2.85×21 FGZCS1.5-2.85×23
Inside Diameter     mm

2680

2680

2680

2850

2850

Effective Length     mm

22500

26000

39000

21000

23000
Design Pressure     Mpa

1.6

1.6

1.6

1.6

1.6

Design Temperature  

204

204

204

201.3

203

Working Pressure   Mpa

1.5

1.5

1.5

1.5

1.5

Working Temperature

200

200

200

197.3

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

800

800

800

1000

963

Effective Volume     m3

134

154.2

227.5

137

150

Gross Weight        Kg

45140

46700

67480

45140

44565

Overall Dimension   mm

24180x

3850×4268

27650x

3454×4268

40650x3454x4268

22634x

3462×4495

24900x

3490×4500

 

ModelItem FGZCS1.5-2.85×24 FGZCS1.5-2.85×25 FGZCS1.5-2.85x26 FGZCS1.5-2.85x26.5 FGZCS1.5-2.85x27
Inside Diameter     mm

2850

2850

2850

2850

2850

Effective Length     mm

24000

25000

26000

26500

27000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

849

963

900

915

Effective Volume     m3

150

161

170

173

180

Gross Weight        Kg

46035

48030

54530

54880

55600

Overall Dimension   mm

25900x

3490×4500

26640x

3640×4495

27634x3640x4495

28134x

3462×4495

28640x

3640×4495

 

ModelItem FGZCS1.5-2.85×29 FGZCS1.5-2.85×36 FGZCS1.5-3x23 FGZCS1.5-3x31 FGZCS1.5-3.2x24.5
Inside Diameter     mm

2850

2850

3000

3000

3200

Effective Length     mm

29000

36000

23000

31000 32000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

900

1220

1000

1200

Effective Volume     m3

190

234

167

227

206

Gross Weight        Kg 58400

70020

56765

70410

62440
Overall Dimension   mm 30634x3640x4495 37634x3462x4495 24875x3516x4804 32875x3516x4804 26570x3750x5027

Product detail pictures:

OEM/ODM Supplier Water Gas Boiler - Autoclave and Boiler – Double Rings detail pictures

OEM/ODM Supplier Water Gas Boiler - Autoclave and Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

We hold strengthening and perfecting our items and repair. At the same time, we get the job done actively to do research and progress for OEM/ODM Supplier Water Gas Boiler - Autoclave and Boiler – Double Rings , The product will supply to all over the world, such as: Leicester, Iraq, Guatemala, All the imported machines effectively control and guarantee the machining precision for the items. Besides, we have a group of high-quality management personnels and professionals, who make the high-quality items and have the ability to develop new merchandise to expand our market home and abroad. We sincerely expect customers come for a blooming business for both of us.
  • The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Henry from Spain - 2017.12.19 11:10
    As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Ivy from Hongkong - 2018.11.02 11:11
    Write your message here and send it to us

    Related products

    • Factory selling Hot Water Tube - Installation & Technology Service – Double Rings

      Factory selling Hot Water Tube - Installation ...

      Installation Procedure Step 1. Slag Extruder put into Foundation| Step 2. Lift Boiler Body to Foundation . Then install the Platform and Stair. Step 3.Connect Boiler,Economizer (Down Part) and Gas Flue. Step 4. Connect Economizer ( Up Parts) and Gas Flue. Step 5.Use asbest rope to Fix Economizer and Gas Flue. Keep no gas leak. Step 6. Lift Dust Cleaner to Foundation. Step 7.Connect and fix the Gas Flue between Dust Cleaner and Economizer . Step 8. Lift I.D Fan to Foundation Step...

    • OEM/ODM Supplier Oil Boiler - Boiler Water Tank – Double Rings

      OEM/ODM Supplier Oil Boiler - Boiler Water Tan...

      Used in Boiler Tank accessories (1) Water inlet pipe: The water inlet pipe of the water tank is generally connected from the side wall, but it can also be connected from the bottom or top. When the water tank USES the pipe network pressure to fill the water, the inlet pipe outlet should be equipped with a floating ball valve or hydraulic valve. Generally, there are not less than 2 floating ball valves. The diameter of the ball float valve is the same as that of the inlet pipe, and each ...

    • Big Discount Biomass Fired Boiler - SHL Bulk Industrial Boiler – Double Rings

      Big Discount Biomass Fired Boiler - SHL Bulk I...

      Introduction: As a new type of mature high-performance with low-pollution clean coal technology. circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics. 1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfuriza...

    • Europe style for Oil Combi Boiler - Coal Boiler Economizer – Double Rings

      Europe style for Oil Combi Boiler - Coal Boile...

      Quality Control 1 Strength Calculation Report for Applied Materials after Inspection Machine inspected. 2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod; 3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler; 4 Hydraulic test report:ensure the standard working pressure and safety; 5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province 6 Manufacturer P...

    • Excellent quality Industrial Boiler Ltd - Double Drum Steam Boiler – Double Rings

      Excellent quality Industrial Boiler Ltd - Doub...

      Coal Steam Boiler-Used in Foods, Textile, Plywood,Paper Brewery,Rice Mill etc.. Introduction : SZL Series assembled water tube boiler adopts longitudinal double drum chain grate boiler. The boiler body is composed of up& down longitudinal drums and convection tube, best heating surface, high thermal efficiency, reasonable design, compact structure, elegant appearance, adequate effect. Two side of Combustion chamber equipped the light pipe water wall tube, up drum equip steam ...

    • OEM Factory for Lpg Steam Boiler - SHL Bulk Industrial Boiler – Double Rings

      OEM Factory for Lpg Steam Boiler - SHL Bulk In...

      Introduction: As a new type of mature high-performance with low-pollution clean coal technology. circulating fluidized bed combustion(CFBC)technology is unlike others that it has a lot of unique characteristics. 1. Circulating fluidized bed is of low-temperature combustion, therefore nitrogen oxides emissions of such boiler is much lower than that of coal-powder boiler, and such boiler could directly desulfurize during combustion process. Circulating fluidized bed boiler with high desulfuriza...