Our target is to consolidate and improve the quality and service of existing products, meanwhile constantly develop new products to meet different customers' demands for Biomass Fired Boiler, Boiler Wood, Water Tube Boiler, We believe that you will be glad with our realistic selling price, high-quality products and solutions and rapid delivery. We sincerely hope you can give us an prospect to provide you and be your best partner!
China Manufacturer for Electric Steam Generator - Double Drum Hot Water Boiler – Double Rings Detail:

Parameter :

SZL Bearing Pressure Hot water Boiler

Main Technology Parameter List

ModelItem SZL2.8-1.0/115/70-AIISZL2.8-1.25/130/70-AII SZL4.2-1.0/115/70-AIISZL4.2-1.25/130/70-AII SZL5.6-1.0/115/70-AIISZL5.6-1.25/130/70-AII
Rated Capacity   2.8T/h 4.2 T/h 5.6 T/h
Rated Working Pressure Mpa 1.0/1.25 1.0/1.25 1.0/1.25
Rated Steam Temp. 115/130 115/130 115/130
Feed Water Temp. 70 70 70
Fuel Consumption  Kg/H ~580 ~900 ~1130
Thermal Efficiency  % 78 80 80
Heating Surface Boiler Body m² 80.5 142 178
Economizer m² 38.5 87.2 122.08
Grate area   m² 4.84 7.78 10.42
Design Fule Bituminous Coal
Max. Transport Weight   30 T ~25T ~26T
Max. Transport Dimension m 6.9×2.5×3.5 Up6.09×3.04×3.6D:7.3×2.86×1.72 6.9×3.33×3.55
Boiler Auxiliary Equipment Model and Specification
Air Blower Model T4-72-11 4ARight 315° T4-72-11 5ARight 225° GC8-1Right 225°
Motor Power N=5.5 Kw N=11 Kw N=11 Kw
Draft Fan Model Y9-26 9DRight 0° Y8-39 9DRight 0° GY8-1Right 0°
Motor Power N=22 Kw N=30 Kw N=37 Kw
Gear Box Model GL-5P GL-10P GL-10P
Motor Power N=0.55 Kw N=1.1Kw N=1.1 Kw
Feed Water Pump Model 1½ GC5x7 2GC-5×5 2GC-5×4
Motor Power N=7.5 Kw N=11 Kw N=11 Kw
Dust Remover XD-4 XD-6 XD-8

 

ModelItem SZL7-1.0/115/70-AIISZL7-1.25/130/70-AII SZL10.5-1.0/115/70-AIISZL10.5-1.25/130/70-AII SZL14-1.0/115/70-AIISZL14-1.25/130/70-AII SZL17.5-1.0/115/70-AIISZL17.5-1.25/130/70-AII
Rated Capacity   7T/h 10.5 T/h 14 T/h 17.5T/h
Rated Working Pressure Mpa 1.0/1.25 1.0/1.25 1.0/1.25 1.0/1.25
Rated Steam Temp. 115/130 115/130 115/130 115/130
Feed Water Temp. 70 70 70 70
Fuel Consumption  Kg/H ~1400 ~1900 ~2700 ~3650
Thermal Efficiency  % 82 82 82 82
Heating Surface Radiation Tube 39.43 37.21 58.4 58.4/68.4
convection bank 213.4 284.68 307.4 307.4/384.8
Economizer m² 122.08 130.8 413 413/521
Grate area   m² 11.99 17.81 22.56 24.52
Design Fule Bituminous Coal (Low location of heat value:19228Ki/kg)
Max. Transport Weight   ~40 T ~43T ~30T ~30T
Max. Transport Dimension 7.9×3.2×3.5 10×3.2×3.5 11×3.2×3.5 12×3.2×3.54

Product detail pictures:

China Manufacturer for Electric Steam Generator - Double Drum Hot Water Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

Our business puts emphasis on the administration, the introduction of talented personnel, as well as the construction of team building, trying hard to further improve the standard and liability consciousness of staff members customers. Our enterprise successfully attained IS9001 Certification and European CE Certification of China Manufacturer for Electric Steam Generator - Double Drum Hot Water Boiler – Double Rings , The product will supply to all over the world, such as: South Africa, Southampton, Oman, We have top engineers in these industries and an efficient team in the research. What is more, we have our own archives mouths and markets in China at low cost. Therefore, we can meet different inquiries from different clients. Please find our website to check more information from our products.
  • This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
    5 Stars By Lauren from Lisbon - 2018.11.11 19:52
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Honorio from Johor - 2017.06.25 12:48
    Write your message here and send it to us

    Related products

    • Competitive Price for Pressure For Boiler - Boiler Valve and Meter – Double Rings

      Competitive Price for Pressure For Boiler - Bo...

      Quality Control 1 Strength Calculation Report for Applied Materials after Inspection Machine inspected. 2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod; 3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler; 4 Hydraulic test report:ensure the standard working pressure and safety; 5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province 6 Manufacturer Produc...

    • Popular Design for Hot Water Heating Boilers - Coal Boiler Biomass Boiler Multi-Tube Dust Cleaner – Double Rings

      Popular Design for Hot Water Heating Boilers -...

      Used in Boiler Multi-tube dust collector belongs to cyclone type dry dust collector, mainly used for boiler and industrial dust collection. Multi-tube dust collector, a kind of cyclone dust collector. Many small cyclone dust collectors (also called cyclones) are combined in a shell and used in parallel. The diameter of the cyclone varies from 100 to 250 mm and can effectively trap 5 to 10 μm dust. It is cast with wear-resistant cast iron and can handle gas with high dust concentration (...

    • China New Product Electric Heating Boilers - Boiler Water Pump – Double Rings

      China New Product Electric Heating Boilers - B...

      Water Pump used in Boiler Components in contact with water—made of  SS304 or SS316 Head:  4~305m Flow rate:0.4~240m^3/h Phase: single phase or three phase Power: 220V/380V Connection: flange or threaded

    • High Quality for Oil Steam Boiler - Coal Boiler Biomass Boiler Multi-Tube Dust Cleaner – Double Rings

      High Quality for Oil Steam Boiler - Coal Boile...

      Used in Boiler Multi-tube dust collector belongs to cyclone type dry dust collector, mainly used for boiler and industrial dust collection. Multi-tube dust collector, a kind of cyclone dust collector. Many small cyclone dust collectors (also called cyclones) are combined in a shell and used in parallel. The diameter of the cyclone varies from 100 to 250 mm and can effectively trap 5 to 10 μm dust. It is cast with wear-resistant cast iron and can handle gas with high dust concentration (...

    • Super Purchasing for Coal Fired Boilers - Coal Boiler Biomass Boiler F.D.Fan – Double Rings

      Super Purchasing for Coal Fired Boilers - Coal...

      FD Fan used in Coal Boiler Industrial centrifugal blower fan is used for steam boilers, which has good quality and high efficiency. According to your requirements, we can provide technical solution and technical solution. Below industrial blower fan picture for your reference.

    • Renewable Design for Hot Water Boilers - Coal Boiler Biomass Boiler Multi-Tube Dust Cleaner – Double Rings

      Renewable Design for Hot Water Boilers - Coal ...

      Used in Boiler Multi-tube dust collector belongs to cyclone type dry dust collector, mainly used for boiler and industrial dust collection. Multi-tube dust collector, a kind of cyclone dust collector. Many small cyclone dust collectors (also called cyclones) are combined in a shell and used in parallel. The diameter of the cyclone varies from 100 to 250 mm and can effectively trap 5 to 10 μm dust. It is cast with wear-resistant cast iron and can handle gas with high dust concentration (...