Our pursuit and company goal is to "Always satisfy our customer requirements". We continue to develop and design superior quality products for both our old and new customers and achieve a win-win prospect for our clients as well as us for autoclave sterilization temperature, boiler technology support, High Pressure Steam Boiler, We sincerely welcome friends to negotiate business and start cooperation. We hope to join hands with friends in different industries to create a brilliant future.
China Factory for Oil Burning Boiler - Double Drum Hot Water Boiler – Double Rings Detail:

Parameter :

SZL Bearing Pressure Hot water Boiler

Main Technology Parameter List

ModelItem SZL2.8-1.0/115/70-AIISZL2.8-1.25/130/70-AII SZL4.2-1.0/115/70-AIISZL4.2-1.25/130/70-AII SZL5.6-1.0/115/70-AIISZL5.6-1.25/130/70-AII
Rated Capacity   2.8T/h 4.2 T/h 5.6 T/h
Rated Working Pressure Mpa 1.0/1.25 1.0/1.25 1.0/1.25
Rated Steam Temp. 115/130 115/130 115/130
Feed Water Temp. 70 70 70
Fuel Consumption  Kg/H ~580 ~900 ~1130
Thermal Efficiency  % 78 80 80
Heating Surface Boiler Body m² 80.5 142 178
Economizer m² 38.5 87.2 122.08
Grate area   m² 4.84 7.78 10.42
Design Fule Bituminous Coal
Max. Transport Weight   30 T ~25T ~26T
Max. Transport Dimension m 6.9×2.5×3.5 Up6.09×3.04×3.6D:7.3×2.86×1.72 6.9×3.33×3.55
Boiler Auxiliary Equipment Model and Specification
Air Blower Model T4-72-11 4ARight 315° T4-72-11 5ARight 225° GC8-1Right 225°
Motor Power N=5.5 Kw N=11 Kw N=11 Kw
Draft Fan Model Y9-26 9DRight 0° Y8-39 9DRight 0° GY8-1Right 0°
Motor Power N=22 Kw N=30 Kw N=37 Kw
Gear Box Model GL-5P GL-10P GL-10P
Motor Power N=0.55 Kw N=1.1Kw N=1.1 Kw
Feed Water Pump Model 1½ GC5x7 2GC-5×5 2GC-5×4
Motor Power N=7.5 Kw N=11 Kw N=11 Kw
Dust Remover XD-4 XD-6 XD-8

 

ModelItem SZL7-1.0/115/70-AIISZL7-1.25/130/70-AII SZL10.5-1.0/115/70-AIISZL10.5-1.25/130/70-AII SZL14-1.0/115/70-AIISZL14-1.25/130/70-AII SZL17.5-1.0/115/70-AIISZL17.5-1.25/130/70-AII
Rated Capacity   7T/h 10.5 T/h 14 T/h 17.5T/h
Rated Working Pressure Mpa 1.0/1.25 1.0/1.25 1.0/1.25 1.0/1.25
Rated Steam Temp. 115/130 115/130 115/130 115/130
Feed Water Temp. 70 70 70 70
Fuel Consumption  Kg/H ~1400 ~1900 ~2700 ~3650
Thermal Efficiency  % 82 82 82 82
Heating Surface Radiation Tube 39.43 37.21 58.4 58.4/68.4
convection bank 213.4 284.68 307.4 307.4/384.8
Economizer m² 122.08 130.8 413 413/521
Grate area   m² 11.99 17.81 22.56 24.52
Design Fule Bituminous Coal (Low location of heat value:19228Ki/kg)
Max. Transport Weight   ~40 T ~43T ~30T ~30T
Max. Transport Dimension 7.9×3.2×3.5 10×3.2×3.5 11×3.2×3.5 12×3.2×3.54

Product detail pictures:

China Factory for Oil Burning Boiler - Double Drum Hot Water Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

With a positive and progressive attitude to customer's interest, our company continuously improves our product quality to meet the needs of customers and further focuses on safety, reliability, environmental requirements, and innovation of China Factory for Oil Burning Boiler - Double Drum Hot Water Boiler – Double Rings , The product will supply to all over the world, such as: Italy, Tajikistan, Angola, We will do our utmost to cooperate & satisfied with you relying on top-grade quality and competitive price and best after service ,sincerely look forward to cooperating with you and make achievements in the future!
  • As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By April from Australia - 2018.09.16 11:31
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Helen from Slovakia - 2018.05.22 12:13
    Write your message here and send it to us

    Related products

    • China Factory for Boiler Operating - Boiler Sample Cooling Collection – Double Rings

      China Factory for Boiler Operating - Boiler Sa...

      Used in Boiler Sampling Cooler  This entry was reviewed by the “Popular Science China” science encyclopedia entry compilation and application project. An instrument used for sampling and cooling of soda-water samples in a boiler room or power plant. The sampling cooler comprises a cooling water tank, an inlet pipe, a flange cover, a outlet pipe, a busbar and a plurality of cooling coils; It can effectively improve the accuracy of water quality analysis, and at the same time ...

    • Ordinary Discount Boilers Suppliers - Double Drum Steam Boiler – Double Rings

      Ordinary Discount Boilers Suppliers - Double D...

      Coal Steam Boiler-Used in Foods, Textile, Plywood,Paper Brewery,Rice Mill etc.. Introduction : SZL Series assembled water tube boiler adopts longitudinal double drum chain grate boiler. The boiler body is composed of up& down longitudinal drums and convection tube, best heating surface, high thermal efficiency, reasonable design, compact structure, elegant appearance, adequate effect. Two side of Combustion chamber equipped the light pipe water wall tube, up drum equip steam ...

    • Lowest Price for Wood Chip Boiler - Boiler Installation Material – Double Rings

      Lowest Price for Wood Chip Boiler - Boiler Ins...

      Used in Boiler DZL 6-1.25-AII STEAM BOILER Installation Material List   Flange Stop Valve   Item  Description   Quantity 1 DN 150    1.6 MPA 1 PC 2 DN 100    1.6 MPA 1 PC 3 DN 80     1.6 MPA 1 PC 4 DN 65     1.6 MPA 2 PCS 5 DN 50     1.6 MPA 3 PCS 6 DN 40     1.6 MPA 1 PC 7 DN 15     1.6 MPA 1 PC   Flange Check Valve   Item  Description   Quantity 1 DN 50     1.6 MPA 1 PC   Flange   Item  Description   Quantity 1 DN 150      2 PCS 2 DN 100       3...

    • Renewable Design for Hot Water Boilers - Boiler Valve and Meter – Double Rings

      Renewable Design for Hot Water Boilers - Boile...

      Quality Control 1 Strength Calculation Report for Applied Materials after Inspection Machine inspected. 2 100%NDT(non-destructive inspection) report of steel plate,tube and welding rod; 3 100% X-ray inspection report (welding seam):to ensure the quality of the entire boiler; 4 Hydraulic test report:ensure the standard working pressure and safety; 5 Third-party inspection report:by Special Equipment Safety Supervision Inspection Institute of Jiang Su Province 6 Manufacturer Produc...

    • High definition Industrial Steam Generator - Double Drum Hot Water Boiler – Double Rings

      High definition Industrial Steam Generator - D...

      Parameter : SZL Bearing Pressure Hot water Boiler Main Technology Parameter List ModelItem SZL2.8-1.0/115/70-AIISZL2.8-1.25/130/70-AII SZL4.2-1.0/115/70-AIISZL4.2-1.25/130/70-AII SZL5.6-1.0/115/70-AIISZL5.6-1.25/130/70-AII Rated Capacity   2.8T/h 4.2 T/h 5.6 T/h Rated Working Pressure Mpa 1.0/1.25 1.0/1.25 1.0/1.25 Rated Steam Temp. ℃ 115/130 115/130 115/130 Feed Water Temp. ℃ 70 70 70 Fuel Consumption  Kg/H ~580 ~900 ~1130 Thermal Efficiency  % 78 80 80 Heating Surface Boil...

    • Low MOQ for Hot Water Heating Boilers - Pellets Shells Husk Biomass Boiler – Double Rings

      Low MOQ for Hot Water Heating Boilers - Pellet...

      Parameter : DZG(L)Horizontal Type Biomass-Burning Steam Boiler Main Technology Parameter List Model DZG2-1.0-S DZL2-1.25-S DZL2-1.57-S DZL2-2.45-S   DZG4-1.25-S DZL4-1.25-S DZL4-1.57-S DZL4-2.45-S DZL6-1.25-S DZL6-1.57-S DZL6-2.45-S  DZL8-1.25-S DZL8-1.57-S DZL8-2.45-S DZL10-1.25-S DZL10-1.57-S DZL10-2.45-S Rated Capacity T/h 2 4 6 8 10 Rated Working Pressure Mpa 1.0/1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 1.25/1.57/2.45 Rated Steam Temp. ℃ 183/194/204/226 194/2...