China Factory for Boiler Operating - Boiler Sample Cooling Collection – Double Rings

Short Description:


Product Detail

Related Video

Feedback (2)

Our group through specialist training. Skilled expert knowledge, sturdy sense of assistance, to fulfill the provider needs of shoppers for installation material, Biomass Heating, Boiler Equipment, The concept of our corporation is "Sincerity, Speed, Services, and Satisfaction". We're going to follow this concept and gain more and far more customers' pleasure.
China Factory for Boiler Operating - Boiler Sample Cooling Collection – Double Rings Detail:

Used in Boiler

Sampling Cooler 
This entry was reviewed by the “Popular Science China” science encyclopedia entry compilation and application project.
An instrument used for sampling and cooling of soda-water samples in a boiler room or power plant.
The sampling cooler comprises a cooling water tank, an inlet pipe, a flange cover, a outlet pipe, a busbar and a plurality of cooling coils;
It can effectively improve the accuracy of water quality analysis, and at the same time the connecting point between the equipment is simple.
 
Structure
Connected with flange cover the top of the cooling water tank is equipped with coil pipe mouth of the flange cover with holes, in the middle of the cooling coil set in cooling water in the box, the outlet and inlet end of the cooling coil respectively through Kong Yanshen to cooling water tank, among them, the entry of the cooling coil and connected to the boiler, the export of cooling coil, directly above the bus slot of the water in the cooling coil by cooling coil exports into confluence worse, bus slot connected at the bottom of the drain;
The bottom of the cooling water tank is provided with a water inlet, the outlet of the water inlet pipe is connected with the water inlet of the cooling water tank;
The top of the cooling water tank is also provided with an outlet, and the inlet of the outlet pipe is connected with the outlet of the cooling water tank .
 
Principle
Sampling cooler used for boiler room or soda assay sample cooling power station, the water in the boiler and heating system mostly higher temperature, and high temperature is not convenient to sampling, also not easy to determine, in the sample should be cool, so let’s introduce the sample of sampling point sampling cooler for cooling, general requirements to ensure traffic in the 500-700 ml/min, the sample can take a 30 to 40 degrees cold, satisfy the People’s Republic of China power industry DL/T 457-91 standard.
 
Characteristics 
The sampling cooler is suitable for sampling medium such as liquid and gas with high temperature. It has the advantages of compact structure, high heat transfer efficiency, convenient cleaning and long service life.
 
Specifications
1: The sampler tube is stainless steel and the housing is carbon steel.
2. Generally, the sampling cooling pipe can be welded and flange with diameter of 10, 12, 14, 16 and 18mm (or optionally specified by the user). The cooling water interface is DN25 with external thread.
3: The general types are qYl-159/0.32, QYl-219/0.40 and QYl-273/0.54.
4: Whether to combine (that is, whether to support, water tank, valve, etc..
 
Sampling procedure
1.Boiler water sampling
The boiler water sample is generally taken out of the continuous drain pipe of the drum and sent to the cooler.
The sampling point should be as close as possible to the outlet of the drain line drain drum and as far as possible before the first drain valve behind the drain drum.2.Sampling of feed water
The sampling point of the water supply is generally set after the feed pump, and a small pipe should be connected to the vertical pipe line of the water supply pipe on the high-pressure feed pipe before the economizer, from which the sample of the water supply is led to the sampling cooler.
The sampling tube of the feed water should be located at a place where the feed water can be mixed after dosing.
3.Sampling of condensed water
The condensate water sampling point is generally located in the condensate water pipe at the outlet of the condensate pump, should not be installed in the condensate pump entrance, because the pressure of the condensate pump entrance is lower than atmospheric pressure.
4.Hydrophobic sampling
The drainage is generally sampled in the drainage tank.
The sampling point is usually located about 300mm away from the bottom of the drain tank.
Steam samples are condensed into water through the sampling cooler.
The steam flow rate in the steam sampler is generally 20-30kg/h.
The requirements for the sample lead – out duct and cooler are the same as for water sampling.by metal corrosion products in the tubes during sampling.
 
Attention
Stainless steel tubes shall be used for sampling. Carbon steel tubes or brass tubes shall not be used to avoid contamination of the samples by metal corrosion products in the tubes during sampling.
sampling


Product detail pictures:

China Factory for Boiler Operating - Boiler Sample Cooling Collection – Double Rings detail pictures

China Factory for Boiler Operating - Boiler Sample Cooling Collection – Double Rings detail pictures


Related Product Guide:
Boiler Structure

We are convinced that with joint endeavours, the small business between us will bring us mutual benefits. We could assure you products quality and competitive selling price for China Factory for Boiler Operating - Boiler Sample Cooling Collection – Double Rings , The product will supply to all over the world, such as: Iraq, Denmark, Angola, When you are keen on any of our items following you view our product list, please feel free to make contact with us for inquiries. You'll be able to send us emails and get in touch with us for consultation and we shall respond to you as soon as we are able to. If it's convenient, you could find out our address in our web site and come to our enterprise. or additional information of our items by yourself. We're generally ready to build lengthy and steady co-operation relations with any possible shoppers within the associated fields.
  • The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Karl from Namibia - 2018.03.03 13:09
    In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
    5 Stars By Anna from India - 2018.06.12 16:22
    Write your message here and send it to us

    Related products

    • 8 Year Exporter Oil Boiler - Well-designed Biomass Pellet Boiler - Coal Boiler Biomass Boiler Reducer – Double Rings – Double Rings

      8 Year Exporter Oil Boiler - Well-designed Bio...

      Reducer used in DR Boiler • The main parts adopt high quality carbon structural refined steel.With high strength, high transmission efficiency and reliable operation, long service life, etc. • Respectively using multilevel, stepless frequency conversion speed regulating mode. User can reasonably match speed reducer according to the different operation condition of boiler.With the features of easy operation, energy saving, etc • With characteristics of large transmission torque and speed...

    • Hot New Products Diesel Boiler - Biomass Hot Water Boiler – Double Rings

      Hot New Products Diesel Boiler - Biomass Hot W...

      Introduction : Biomass boiler is horizontal three-back water fire pipe composite boiler. The fuel can be Biomass,coal,wood,rice husk,shells,pellets,bagasse,waste etc.. Display Feature: 1. High thermal efficiency 2. By mechanize operation, reduce intensity of labour of stoker. 3. Easy for installation, when on site, only install slag remover, valve, pipe, water and power, etc., the boiler can be launched into running, additionally, the firing is fast. 4. Easy for installation and moving, save...

    • Cheap price China Industrial Boiler - Coal Boiler Biomass Boiler F.D.Fan – Double Rings

      Cheap price China Industrial Boiler - Coal Boi...

      FD Fan used in Coal Boiler Industrial centrifugal blower fan is used for steam boilers, which has good quality and high efficiency. According to your requirements, we can provide technical solution and technical solution. Below industrial blower fan picture for your reference.

    • Massive Selection for Wood Pellet Boiler - Boiler Electric Control – Double Rings

      Massive Selection for Wood Pellet Boiler - Boi...

      More Photos Electric Control Container Overview 2-4T 6T 10T 15T 20T 25T Sheet 1: 2t steam boiler electrical instrument control system configuration (common configuration 1.25Mpa) Features name Specification unit Qty Brand Electrical control           Induced draft fan control 11KW  Star Delta Start  set  1  Zhengtai Blower control  3KW  Direct start  set  1  Grate control  0.55KW  Direct start  set  1  Coal machine control 1.1KW  Direct start  set  1  Slag machine control ...

    • Coal Fired Thermal Oil Boiler - Pressure Vessel – Double Rings

      Coal Fired Thermal Oil Boiler - Pressure Vesse...

      Introduction: Pressure vessel equipment plays an important role in the petrochemical industry, the energy industry, scientific research and military sectors etc. Pressure vessel container body consist of cylinder, sealing head, flange, sealing elements, open pore and connected pipe, bearing. In addition, also equipped with safety devices, meter and safety internals for protection purpose . Pressure Vessel Main Performance Parameter List Steam Pressure1.0Mpa Inlet Temperature 250℃ S...

    • Trending Products Boiler System - Coal Boiler Biomass Boiler I.D.Fan – Double Rings

      Trending Products Boiler System - Coal Boiler ...

      I.D fan used in Coal Boiler boiler induced draft fan is designed for the industrial boiler (1-20T / h) or domestic boiler equipped with various coal quality and smoke and dust removal device. It can be selected for the same air inlet conditions and performance, but the high temperature is ≤ 250 ℃. Before induced draft, a dust removal device with efficiency ≤ 85% must be installed to ensure that the dust content of flue gas entering the fan is 400mg/m3