"Based on domestic market and expand abroad business" is our progress strategy for pipe for hot water boiler, Industrial Electric Boiler, Oil Condensing Boilers, We believe that you will be glad with our realistic selling price, high-quality products and solutions and rapid delivery. We sincerely hope you can give us an prospect to provide you and be your best partner!
Low MOQ for Hot Water Heating Boilers - Autoclave and Boiler – Double Rings Detail:

Autoclave-Popular used in ACC Plant,Flyash Plant,Building Material etc..

Autoclave Feature

1, the first domestic production of autoclave professional factory.
2, assembly line production, welding all the automation, quality and stability.
3, all the pressure components 100% X-ray film detection, advanced detection methods.
4, the product as a whole factory, advanced and reasonable structure, short installation period, the investment cost is low.
5, fully furnished, by manual or computer control.
    Autoclave use:
    Autoclave steam curing equipment for large, can be used for steam-cured sand lime bricks, fly ash bricks, aerated concrete blocks, high-strength concrete pole, pipe and other concrete products, but also for timber, medicine, chemical industry, glass, insulation materials and other industries.
autoclave and boiler ACC

Autoclave Specification

Autoclave Series

Main Technology Parameter List

ModelItem FGZCS1.0-1.65×21 FGZCS1.3-2×21 FGZCS1.3-2×22 FGZCS1.3-2×26 FGZCS1.3-2×27.5 FGZCS1.3-2x30
Inside Diameter     mm

1650

2000

2000

2000

2000

2000

Effective Length     mm

21000

21000

22000

26000

27500 30000
Design Pressure     Mpa

1.08

1.4

1.4

1.4

1.4

1.4

Design Temperature  

187

197.3

197.3

197.3

197.3

197.3

Working Pressure   Mpa

1.0

1.3

1.3

1.3

1.3

1.3

Working Temperature

183

193.3

193.3

193.3

193.3

193.3

Actuating Medium

Saturated Steam , condensed water

Inside Rail Distance  mm

600

448

600

750

600

600

Effective Volume     m3

46

68

71

84

88.5

96.4

Gross Weight        Kg

18830

25830

26658

30850

32170

34100

Overall Dimension   mm

21966x

2600×2803

22300x

2850×3340

23300x2850x3340

27300x

2850×3340

28800x

2850×3340

31300x

2850×3340

 

ModelItem FGZCS1.5-2.68×22.5 FGZCS1.5-2.68×26 FGZCS1.5-2.68x39 FGZCS1.5-2.85×21 FGZCS1.5-2.85×23
Inside Diameter     mm

2680

2680

2680

2850

2850

Effective Length     mm

22500

26000

39000

21000

23000
Design Pressure     Mpa

1.6

1.6

1.6

1.6

1.6

Design Temperature  

204

204

204

201.3

203

Working Pressure   Mpa

1.5

1.5

1.5

1.5

1.5

Working Temperature

200

200

200

197.3

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

800

800

800

1000

963

Effective Volume     m3

134

154.2

227.5

137

150

Gross Weight        Kg

45140

46700

67480

45140

44565

Overall Dimension   mm

24180x

3850×4268

27650x

3454×4268

40650x3454x4268

22634x

3462×4495

24900x

3490×4500

 

ModelItem FGZCS1.5-2.85×24 FGZCS1.5-2.85×25 FGZCS1.5-2.85x26 FGZCS1.5-2.85x26.5 FGZCS1.5-2.85x27
Inside Diameter     mm

2850

2850

2850

2850

2850

Effective Length     mm

24000

25000

26000

26500

27000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

849

963

900

915

Effective Volume     m3

150

161

170

173

180

Gross Weight        Kg

46035

48030

54530

54880

55600

Overall Dimension   mm

25900x

3490×4500

26640x

3640×4495

27634x3640x4495

28134x

3462×4495

28640x

3640×4495

 

ModelItem FGZCS1.5-2.85×29 FGZCS1.5-2.85×36 FGZCS1.5-3x23 FGZCS1.5-3x31 FGZCS1.5-3.2x24.5
Inside Diameter     mm

2850

2850

3000

3000

3200

Effective Length     mm

29000

36000

23000

31000 32000
Design Pressure     Mpa

1.6

Design Temperature  

203

Working Pressure   Mpa

1.5

Working Temperature

199

Actuating Medium

Saturated Steam , condensed water

 
Inside Rail Distance  mm

963

900

1220

1000

1200

Effective Volume     m3

190

234

167

227

206

Gross Weight        Kg 58400

70020

56765

70410

62440
Overall Dimension   mm 30634x3640x4495 37634x3462x4495 24875x3516x4804 32875x3516x4804 26570x3750x5027

Product detail pictures:

Low MOQ for Hot Water Heating Boilers - Autoclave and Boiler – Double Rings detail pictures

Low MOQ for Hot Water Heating Boilers - Autoclave and Boiler – Double Rings detail pictures


Related Product Guide:
Boiler Structure

Our target is always to satisfy our customers by offering golden support, superior value and high quality for Low MOQ for Hot Water Heating Boilers - Autoclave and Boiler – Double Rings , The product will supply to all over the world, such as: Gambia, Durban, California, To achieve reciprocal advantages, our company is widely boosting our tactics of globalization in terms of communication with overseas customers, fast delivery, the best quality and long-term cooperation. Our company upholds the spirit of "innovation, harmony, team work and sharing, trails, pragmatic progress". Give us a chance and we'll prove our capability. With your kind help, we believe that we can create a bright future with you together.
  • This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
    5 Stars By Nicole from Portugal - 2018.10.31 10:02
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Jessie from Maldives - 2018.06.12 16:22
    Write your message here and send it to us

    Related products

    • Best Price for Heating Water Boiler - SZS Gas Oil PLG Boiler – Double Rings

      Best Price for Heating Water Boiler - SZS Gas ...

      Introduction : SZS series boiler body is longitudinal 2-drum, D-type chamber combustion strueture. The furnace is on right side and the convection bank tube is on left side. The body is fixed on the body chassis by flexible supports in the middle and two ends of the lower drum,can secure to let the whole boiler body to expand sideways. Surround furnace there are narrow space membrane cooling tube wall. It is totally sealed and separated between the membrane wall on furnace left side and the c...

    • Competitive Price for Pressure For Boiler - Boiler Steam Distribution Cylinder – Double Rings

      Competitive Price for Pressure For Boiler - Bo...

      Used in Boiler Introduction The sub-cylinder is the main supporting equipment of the boiler. It is used to distribute the steam generated during the operation of the boiler to various pipelines. The sub-cylinder is a pressure-bearing equipment and belongs to a pressure vessel. Its pressure-bearing capacity and capacity should correspond to the supporting boiler . Main pressure components The main pressure components of the sub-cylinder are: head, shell material, etc. Usage The sub-cylin...

    • Fixed Competitive Price Heat Boilers - Boiler Flue – Double Rings

      Fixed Competitive Price Heat Boilers - Boiler ...

      Used in Boiler Introduction Industrial smoke exhaust, air into the pipe, the pipe is equipped with a damper (valve) to regulate the wind speed and pressure in the pipe. It is composed of furnace wall, partial heating surface pipe and cladding wall pipe to guide the flow of smoke, and through each heating surface for heat exchange, divided into horizontal flue and tail flue. The main smoke duct section size of the large capacity boiler is very large, in order to bear and transfer the loa...

    • Factory Cheap Hot Wood Chip Biomass Boiler - Vertical Gas Oil Boiler – Double Rings

      Factory Cheap Hot Wood Chip Biomass Boiler - V...

      Introduction : 1. Compact structure, small installation area, easy to install. 2. Good heating surface , low exhaust gas temperature 3. The world famous original burner, automatic and high efficient combustion, high combustion efficiency 4. Microcomputer automatic controller, overpressure protection and ultra-low water level automatic protection and automatic feed water . 5. Super thickness insulating layer design, good insulation effect, boiler surface temperature low, low losing he...

    • Factory source Coal Fired Boiler - Boiler Sample Cooling Collection – Double Rings

      Factory source Coal Fired Boiler - Boiler Samp...

      Used in Boiler Sampling Cooler  This entry was reviewed by the “Popular Science China” science encyclopedia entry compilation and application project. An instrument used for sampling and cooling of soda-water samples in a boiler room or power plant. The sampling cooler comprises a cooling water tank, an inlet pipe, a flange cover, a outlet pipe, a busbar and a plurality of cooling coils; It can effectively improve the accuracy of water quality analysis, and at the same time ...

    • Best Price for China Coal Boiler - LPG Pressure Tank – Double Rings

      Best Price for China Coal Boiler - LPG Pressur...

      Introduction: Pressure vessel equipment plays an important role in the petrochemical industry, the energy industry, scientific research and military sectors etc. Pressure vessel container body consist of cylinder, sealing head, flange, sealing elements, open pore and connected pipe, bearing. In addition, also equipped with safety devices, meter and safety internals for protection purpose . Pressure Vessel Main Performance Parameter List Steam Pressure1.0Mpa Inlet Temperature 250℃ S...